COLTER'S BAR B Q
3904 W Camp Wisdom Rd, Dallas, TX, 75237
Dallas Consumer Health Division score guide. 79–70: Follow-up inspection required within 30 days.
Most recent inspection
- Date
- September 20, 2026
- Type
- Routine
- Result
- Score 77
- Risk category
- Not reported
- Cited findings
- 15
- Jurisdiction
- Dallas County (City of Dallas), TX
Violations (15)
- 2
Certified Food Protection Manager and Food Handler Certification
228.31(e) Establishment failed to maintain the certificates of completion of the food handler training course for each food employee.
- 16
Food-contact surfaces: cleaned & sanitized
4-601.11(A) Establishment failed to clean ice machine at a frequency to preclude the accumulation of soil or mold. Observed can opener with aged debris on blade. Clean blade frequently, replace if rusted or chipped.
- 16
Food-contact surfaces: cleaned & sanitized
4-703.11(C)(4) OBSERVED SANITIZER BUCKET AT 0ppm CHLORINE AND QUAT SANITIZER (no sanitizer in the sanitizer buckets)
- 21
Proper Hot Holding Temperatures
3-501.16(A)(1) OBSERVED FOODS NOT HELD ABOVE 135*F in hot holding - Pork @ 108*F - Gravy @ 105*F - 1 Hot Holding unit displaying temp of 123*F
- 36
Thermometers provided and accurate
4-204.112(B) Establishment failed to place a thermometer in the warmest part of the refrigeration unit.
- 37
Food properly labeled; original container
3-302.12 MUST LABEL ALL FOOD CONTAINERS WITH POWDERED FOODS
- 39
Contamination prevented during food preparation, storage and display
3-307.11 OBSERVED INSIDE WALK IN FREEZER: ICE FORMATION / FROST FALL FROM AC UNIT, AND IS ACTIVELY COVERING A BOX OF FOOD. Keep foods away from the WALK IN FREEZER's ice fall and have WIF AC checked out.
- 40
Personal Cleanliness
2-303.11 OBSERVED FOOD PREP EMPLOYEE WEARING WRISTWARE SUCH AS JEWELRY/WATCH, please do not have any accessories on hands or arms
- 43
In-use utensils; properly stored
3-304.12 Observed in-use dispensing utensils with handles down in the food.
- 47
Food and non-food-contact surfaces cleanable, properly designed, constructed, and used
4-501.11(A) Observed used cutting blocks and boards that can no longer be effectively cleaned and sanitized. Observed WALK IN COOLER and WALK IN FREEZER doors do not completely close/seal. Observed WIF has AC forming ice from pipes, possible leak or defrost issue.
- 48
Warewashing facilities, installed, maintained, used, test strips
4-302.14 OBSERVED NO TEST QUAT STRIPS PROVIDED BY ESTABLISHMENT WHEN INSPECTOR REQUESTED IT
- 51
Plumbing installed; proper backflow devices
5-202.11(A) Observed leak @ 3 comp sink pipe below
- 52
Sewage and waste water properly disposed
5-402.11 OBSERVED DISHWASHER DRAIN PIPES ARE GOING INTO THE GROUND DRAINS, must have a 1 inch air gap.
- 55
Physical facilities installed, maintained, and clean
6-501.11 OBSERVED INSTANCES OF MINOR DAMAGED SURFACES ON WALL AND IMPROPER CEILING TILES AT KITCHEN. Please repair around the walls and ceilings of the kitchen
- 56
Adequate ventilation and lighting; designated areas used
6-403.11 OBSERVED INSTANCES WHERE PERSONAL ITEMS SUCH AS CELL PHONES WERE STORED NEXT TO OR ONTOP OF FOOD PREP AREAS / SURFACES.
Earlier inspections on file
Source: Dallas County (City of Dallas), TX health department. Data refreshed October 16, 2026. Results are shown in the health department's own wording. This record is provided for general information; confirm current status with the health department before relying on it.